TECHNICAL SELECTION NOTES · UPDATED 2026-10-17

Reviewing ASTM E595 Low-Outgassing Evidence for Fiber Assemblies

ASTM E595 is a material-screening method under specified vacuum conditions, not complete qualification of a fiber assembly for vacuum, clean or space systems. Match material part, mix, cure state and test conditions, and separate screening data from assembly contamination and optical validation. A database listing is not product certification.

Direct answer

ASTM E595 is a material-screening method under specified vacuum conditions, not complete qualification of a fiber assembly for vacuum, clean or space systems. Match material part, mix, cure state and test conditions, and separate screening data from assembly contamination and optical validation. A database listing is not product certification.

Separate material screening from assembly suitability

The ASTM E595 public scope identifies material screening and explains that configuration, temperature and processing affect real contamination. The NASA data guide also ties records to material and cure conditions. A database number alone is insufficient for an adhesive purchase.

Use this guide for vacuum or contamination-sensitive OEM reviews. It creates no universal test requirement for telecom cords and asserts no ARRANEX vacuum or space-qualified offering.

TermWhat it describesUnsupported inference
TMLSpecimen mass-loss percentage under the testAll lost mass deposits on an optical surface
CVCMCollected condensables relative to initial specimen massActual contamination in every system
WVRWater regained after testingEquivalent to CVCM
Screening acceptanceStated conditions and criteria satisfiedWhole-system suitability

Match the material's processed state

Record manufacturer, full part, mixture and batch before comparing cure time, temperature and atmosphere. If production uses different mixing or processing, request the limits of the cited evidence.

Blank cure fields in the NASA guide indicate unknown conditions, not an assumed room-temperature cure. Material owners should review old data, formulation changes and critical batches. Historical listing does not establish identical results for every later batch.

Retain the denominator in a percentage

For an original calculation only, assume 100 mg initial specimen mass and 0.05 mg collected condensables. CVCM on that basis is 0.05%. These are not measured material data or an acceptance limit set by this guide.

Multiplying that percentage by complete assembly mass does not predict deposits on an optical face. Exposure, location, temperatures and collection boundaries differ. Keep screening values separate from the system contamination model.

Evidence for material and assembly suppliers

StageRequested recordsQuestion
IdentityPart, batch, mixtureIs this the tested material?
Process stateCure, post-processing, storageDoes production match the specimen?
Test reportEdition, conditions, TML/CVCM and criteriaWhat was actually established?
ConstructionAmount, location, exposure, nearby opticsWhich contamination paths matter?
Functional validationAgreed optical/contamination checksWhat remains beyond material screening?

This is a review checklist, not a vacuum-bake recipe. Use approved material and assembly procedures for heating, evacuation or post-processing rather than modifying finished parts to pursue a lower number.

Procurement FAQ

  1. Does a NASA database listing establish NASA certification? Listing data and product certification are different; do not make that claim.
  2. Does low outgassing mean low insertion loss? They address different properties and need corresponding evidence.
  3. Can common TML/CVCM numbers be applied universally? Set requirements for the actual system rather than converting historical screening values into universal mandates.
  4. Can matching adhesive names without cure data be accepted automatically? Identify or disclose the missing conditions first.
  5. What belongs in the first RFQ? Material identity, process state, verifiable report, assembly boundary and responsibility for subsequent validation.

Related products and reading

Product and solution links support requirements review. Suitability and scope depend on agreed specifications, without implying new specialized-environment capability or certification.

Contact an engineer with drawings and validation requirements

Sources and review date

Reviewed on 2026-10-17. Original source dates remain separate from this review. Procurement tables are editorial recommendations, and calculations illustrate stated assumptions rather than actual product data.

Sources checked: 2026-10-17

RFQ / ENGINEERING REVIEW

Send what you know. We will help define the rest.

Interfaces, fiber count, application, environment, quantity or a drawing are enough to start.

Open email to inquire

Send to: xsconcom@gmail.com · Your email app opens. Review the message and send it there.

Drawings, BOMs and existing samples are welcome
Talk to an engineer