TECHNICAL SELECTION NOTES · UPDATED 2026-10-02

Insertion loss vs return loss: IL, RL and assembly acceptance

IL describes reduced transmitted power; RL is the incident-to-returned power ratio. Under matching conditions lower IL and higher RL are desirable. Specify the DUT, wavelength, method and limits separately.

DIRECT ANSWER / 01

Insertion loss and return loss describe different effects

Insertion loss (IL) describes reduced transmitted power; return loss (RL) is the incident-to-returned power ratio expressed in dB. Under matching conditions, lower IL and higher RL are desirable, but the numbers are not interchangeable and results from different conditions cannot be ranked directly.

Use this for RFQs, sample-report comparisons and incoming acceptance. IEC 61300-3-4 addresses component attenuation measurement and IEC 61300-3-6 addresses RL. Citing their public scope is not product certification. Distinguish a connector’s RL from whole-link optical return loss by defining the object under test.

SELECTION MATRIX / 02

Purchasing decision matrix

ItemIdentifyCorrect actionAvoid
ILTransmission attenuation, DUT and reference boundarySpecify a maximum and the corresponding methodTreating component loss as total link loss
RLReturned power, port and wavelengthSpecify a minimum and identify the DUTAssuming a smaller RL is better
End faceAPC/UPC, mating part and inspection stateMatch end faces to equipment requirementsTreating a polish label as a measurement
Comparison conditionsMethod, wavelength, cords and assembly revisionAlign conditions before comparing resultsComparing numbers without methods
ReportLane IL/RL, criteria and exceptionsRetain revision, ports, conditions and resultsProviding only an average

RFQ INPUTS / 03

Minimum inputs a supplier can verify

CategoryRequired input or confirmation
Metric definitionIL maximum, RL minimum, DUT, wavelength and scope
Reference conditionsMethod revision, mating part, reference setup and face condition
Deliverable recordAssembly/lane IDs, directions, results, verdict and report revision

BUYER FAQ / 04

Purchasing FAQ

01

Does passing IL prove passing RL?

No. They describe different effects and need separate measurements and criteria.

02

What does a larger RL mean?

Under the same definition, less power returns relative to incident power; project criteria still apply.

03

Is APC suitable for every device?

No. Match the specified interface; do not substitute a polish solely to seek a desired RL number.

04

Are component RL and link ORL equivalent?

Do not assume equivalence. Identify the DUT, path and conditions to avoid comparing different scopes.

05

Can an RFQ start without numeric limits?

Yes. Provide application/equipment requirements and leave limits/methods open; catalogue values must not silently become guarantees.

SOURCES / 05

Sources and applicability

Sources checked: 2026-10-02. This guide clarifies purchasing fields; it does not replace current equipment data sheets, full standards or the approved project drawing.

  1. IEC 61300-3-4:2023 — Optical component attenuation methods
  2. IEC 61300-3-6:2008 — Return loss measurement

RFQ / ENGINEERING REVIEW

Send what you know. We will help define the rest.

Interfaces, fiber count, application, environment, quantity or a drawing are enough to start.

Open email to inquire

Send to: xsconcom@gmail.com · Your email app opens. Review the message and send it there.

Drawings, BOMs and existing samples are welcome
Talk to an engineer